A sump pump runs constantly when its float is stuck up, its check valve lets water drop back into the pit, groundwater keeps flowing in after storms, the pump is too small for the volume of water, or the discharge line is blocked. Running nonstop during a heavy storm can be normal. Running nonstop on a dry week is a sign of a problem.

Read the Pump’s Behavior

Spend a few minutes watching:

Float Problems

The float needs to move freely to tell the pump when to stop. A cord, debris, or the side of the pit can hold it in the on position. Unplug the pump before checking, and never reach into the pit while it has power.

Check Valve and Discharge

The check valve should only let water flow out. If it fails, pumped water falls back and refills the pit. Outside, the discharge end should be clear and should empty well away from the foundation so water does not soak right back in.

Size and Age

In wet conditions, a smaller or older pump may simply fall behind. A plumber can compare the pump’s capacity with how quickly your pit fills and recommend a better match if needed.

A pump that never rests will wear out far sooner than one that runs normally. Before the next storm, a service visit can pinpoint the faulty part. While a plumber is there, a look at grading and drainage near the foundation can help reduce the load on the pump. Keep the pit clear of debris. Call JPR Plumbing at (833) 603-1840.

Leave a Reply

Your email address will not be published. Required fields are marked *